30 lines
814 B
Markdown
30 lines
814 B
Markdown
## Description
|
|
|
|
The SMB2 scanner module simply scans the remote hosts and determines if they support the SMB2 protocol.
|
|
|
|
## Verification Steps
|
|
|
|
1. Do: ```use auxiliary/scanner/smb/smb2```
|
|
2. Do: ```set RHOSTS [IP]```
|
|
3. Do: ```set THREADS [number of threads]```
|
|
4. Do: ```run```
|
|
|
|
## Scenarios
|
|
|
|
```
|
|
msf > use auxiliary/scanner/smb/smb2
|
|
msf auxiliary(smb2) > set RHOSTS 192.168.1.150-165
|
|
RHOSTS => 192.168.1.150-165
|
|
msf auxiliary(smb2) > set THREADS 16
|
|
THREADS => 16
|
|
msf auxiliary(smb2) > run
|
|
|
|
[*] 192.168.1.162 supports SMB 2 [dialect 255.2] and has been online for 618 hours
|
|
[*] Scanned 06 of 16 hosts (037% complete)
|
|
[*] Scanned 13 of 16 hosts (081% complete)
|
|
[*] Scanned 14 of 16 hosts (087% complete)
|
|
[*] Scanned 16 of 16 hosts (100% complete)
|
|
[*] Auxiliary module execution completed
|
|
msf auxiliary(smb2) >
|
|
```
|