cmd/brew-postgresql-upgrade-database: fix initdb issues.

* Add `safe_system` to `initdb` call to catch errors

If the `initdb` step fails (which it can if the options passed are
invalid), then the script will continue having marked `initdb_run` as
`true`. This causes the script to continue to `pg_upgrade` step which
will fail, ultimately triggering the `ensure` block. Since `initdb_run`
is `true`, the script tries to remove `datadir` which we don't want
since that step failed.

The change here adds `safe_system` to ensure if the `initdb` step fails,
it correctly bails out.

* Add -X to `psql` call to ignore `.psqlrc` files

Customizations in `.psqlrc` files can make the output of `psql`
unpredictable, which can break parsing of the command's output. Using -X
causes `psql` to ignore any such files and use the default output
behavior, which can be parsed with consistency.
master
Logan Leger 2019-06-11 13:05:47 -05:00 committed by Mike McQuaid
parent 2986937737
commit 02df2994aa
1 changed files with 3 additions and 3 deletions

View File

@ -64,8 +64,8 @@ begin
sql_for_lc_collate = "SELECT setting FROM pg_settings WHERE name LIKE 'lc_collate';" sql_for_lc_collate = "SELECT setting FROM pg_settings WHERE name LIKE 'lc_collate';"
sql_for_lc_ctype = "SELECT setting FROM pg_settings WHERE name LIKE 'lc_ctype';" sql_for_lc_ctype = "SELECT setting FROM pg_settings WHERE name LIKE 'lc_ctype';"
lc_collate = Utils.popen_read("#{old_bin}/psql", "postgres", "-qtAc", sql_for_lc_collate).strip lc_collate = Utils.popen_read("#{old_bin}/psql", "postgres", "-qtAX", "-U", ENV["USER"], "-c", sql_for_lc_collate)
lc_ctype = Utils.popen_read("#{old_bin}/psql", "postgres", "-qtAc", sql_for_lc_ctype).strip lc_ctype = Utils.popen_read("#{old_bin}/psql", "postgres", "-qtAX", "-U", ENV["USER"], "-c", sql_for_lc_ctype)
initdb_args = [] initdb_args = []
initdb_args += ["--lc-collate", lc_collate] unless lc_collate.empty? initdb_args += ["--lc-collate", lc_collate] unless lc_collate.empty?
initdb_args += ["--lc-ctype", lc_ctype] unless lc_ctype.empty? initdb_args += ["--lc-ctype", lc_ctype] unless lc_ctype.empty?
@ -79,7 +79,7 @@ begin
moved_data = true moved_data = true
(var/"postgres").mkpath (var/"postgres").mkpath
system "#{bin}/initdb", *initdb_args, "#{var}/postgres" safe_system "#{bin}/initdb", *initdb_args, "#{var}/postgres"
initdb_run = true initdb_run = true
(var/"log").cd do (var/"log").cd do