diff --git a/src/js/msp.js b/src/js/msp.js index f2219ba6..6eef7f7b 100644 --- a/src/js/msp.js +++ b/src/js/msp.js @@ -50,6 +50,10 @@ const MSP = { packet_error: 0, unsupported: 0, + MIN_TIMEOUT: 250, + MAX_TIMEOUT: 2000, + timeout: 250, + last_received_timestamp: null, listeners: [], @@ -318,25 +322,27 @@ const MSP = { if (callback_msp) { callback_msp(); } - return; + return false; } if (code === undefined || !serial.connectionId) { - return; + return false; } - let bufferOut; - if (code <= 254) { - bufferOut = this.encode_message_v1(code, data); - } else { - bufferOut = this.encode_message_v2(code, data); - } - - const obj = {'code': code, 'requestBuffer': bufferOut, 'callback': callback_msp ? callback_msp : false, 'timer': false, 'callbackOnError': doCallbackOnError}; + const bufferOut = code <= 254 ? this.encode_message_v1(code, data) : this.encode_message_v2(code, data); + const obj = { + 'code': code, + 'requestBuffer': bufferOut, + 'callback': callback_msp ? callback_msp : false, + 'timer': false, + 'callbackOnError': doCallbackOnError, + 'start': performance.now(), + }; let requestExists = false; - for (const value of MSP.callbacks) { - if (value.code === code) { + + for (const instance of MSP.callbacks) { + if (instance.code === code) { // request already exist, we will just attach requestExists = true; break; @@ -345,18 +351,26 @@ const MSP = { if (!requestExists) { obj.timer = setInterval(function () { - console.warn(`MSP: data request timed-out: ${code} ID: ${serial.connectionId} TAB: ${GUI.active_tab}`); + console.warn(`MSP: data request timed-out: ${code} ID: ${serial.connectionId} TAB: ${GUI.active_tab} TIMEOUT: ${MSP.timeout}`); + serial.send(bufferOut, function (_sendInfo) { + obj.stop = performance.now(); + const executionTime = Math.round(obj.stop - obj.start); + MSP.timeout = Math.max(MSP.MIN_TIMEOUT, Math.min(executionTime, MSP.MAX_TIMEOUT)); + }); - serial.send(bufferOut, false); - }, 1000); // we should be able to define timeout in the future + }, MSP.timeout); } MSP.callbacks.push(obj); // always send messages with data payload (even when there is a message already in the queue) if (data || !requestExists) { + if (MSP.timeout > MSP.MIN_TIMEOUT) { + MSP.timeout--; + } + serial.send(bufferOut, function (sendInfo) { - if (sendInfo.bytesSent == bufferOut.byteLength) { + if (sendInfo.bytesSent === bufferOut.byteLength) { if (callback_sent) { callback_sent(); } @@ -370,17 +384,18 @@ const MSP = { /** * resolves: {command: code, data: data, length: message_length} */ - promise: function(code, data) { - const self = this; - return new Promise(function(resolve) { - self.send_message(code, data, false, function(_data) { - resolve(_data); + promise: async function(code, data) { + const self = this; + + return new Promise(function(resolve) { + self.send_message(code, data, false, function(_data) { + resolve(_data); + }); }); - }); }, callbacks_cleanup: function () { - for (let index = 0; index < this.callbacks.length; index++) { - clearInterval(this.callbacks[index].timer); + for (const callback of this.callbacks) { + clearInterval(callback.timer); } this.callbacks = []; diff --git a/src/js/msp/MSPHelper.js b/src/js/msp/MSPHelper.js index f3707a89..3dfcbb91 100644 --- a/src/js/msp/MSPHelper.js +++ b/src/js/msp/MSPHelper.js @@ -147,8 +147,6 @@ MspHelper.prototype.process_data = function(dataHandler) { FC.CONFIG.mode = data.readU32(); FC.CONFIG.profile = data.readU8(); - TABS.pid_tuning.checkUpdateProfile(false); - sensor_status(FC.CONFIG.activeSensors); break; case MSPCodes.MSP_STATUS_EX: @@ -173,8 +171,6 @@ MspHelper.prototype.process_data = function(dataHandler) { FC.CONFIG.armingDisableCount = data.readU8(); // Flag count FC.CONFIG.armingDisableFlags = data.readU32(); } - - TABS.pid_tuning.checkUpdateProfile(true); } sensor_status(FC.CONFIG.activeSensors); @@ -274,10 +270,10 @@ MspHelper.prototype.process_data = function(dataHandler) { FC.ANALOG.mAhdrawn = data.readU16(); FC.ANALOG.rssi = data.readU16(); // 0-1023 FC.ANALOG.amperage = data.read16() / 100; // A - FC.ANALOG.last_received_timestamp = Date.now(); if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_41)) { FC.ANALOG.voltage = data.readU16() / 100; } + FC.ANALOG.last_received_timestamp = Date.now(); break; case MSPCodes.MSP_VOLTAGE_METERS: FC.VOLTAGE_METERS = []; @@ -727,7 +723,6 @@ MspHelper.prototype.process_data = function(dataHandler) { } break; case MSPCodes.MSP_SET_MOTOR: - console.log('Motor Speeds Updated'); break; case MSPCodes.MSP_UID: FC.CONFIG.uid[0] = data.readU32(); @@ -1728,8 +1723,8 @@ MspHelper.prototype.process_data = function(dataHandler) { if (self.mspMultipleCache.length > 0) { const partialBuffer = []; - for (let i = 0; i < self.mspMultipleCache.length; i++) { - partialBuffer.push8(self.mspMultipleCache[i]); + for (const instance of self.mspMultipleCache) { + partialBuffer.push8(instance); } MSP.send_message(MSPCodes.MSP_MULTIPLE_MSP, partialBuffer, false, dataHandler.callbacks); @@ -1746,11 +1741,12 @@ MspHelper.prototype.process_data = function(dataHandler) { console.log(`Unknown code detected: ${code}`); } else { console.log(`FC reports unsupported message error: ${code}`); - - if (code === MSPCodes.MSP_SET_REBOOT) { - TABS.onboard_logging.mscRebootFailedCallback(); - } } + + if (code === MSPCodes.MSP_SET_REBOOT) { + TABS.onboard_logging.mscRebootFailedCallback(); + } + } else { console.warn(`code: ${code} - crc failed`); } diff --git a/src/js/serial_backend.js b/src/js/serial_backend.js index 29639dd1..d7bf44ea 100644 --- a/src/js/serial_backend.js +++ b/src/js/serial_backend.js @@ -491,7 +491,7 @@ function connectCli() { $('#tabs .tab_cli a').click(); } -function onConnect() { +async function onConnect() { if ($('div#flashbutton a.flash_state').hasClass('active') && $('div#flashbutton a.flash').hasClass('active')) { $('div#flashbutton a.flash_state').removeClass('active'); $('div#flashbutton a.flash').removeClass('active'); @@ -532,13 +532,12 @@ function onConnect() { $('#tabs ul.mode-connected').show(); - MSP.send_message(MSPCodes.MSP_FEATURE_CONFIG, false, false); + await MSP.promise(MSPCodes.MSP_FEATURE_CONFIG); if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_33)) { - MSP.send_message(MSPCodes.MSP_BATTERY_CONFIG, false, false); + await MSP.promise(MSPCodes.MSP_BATTERY_CONFIG); } - MSP.send_message(MSPCodes.MSP_STATUS_EX, false, false); - MSP.send_message(MSPCodes.MSP_DATAFLASH_SUMMARY, false, false); - + await MSP.promise(semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_32) ? MSPCodes.MSP_STATUS_EX : MSPCodes.MSP_STATUS); + await MSP.promise(MSPCodes.MSP_DATAFLASH_SUMMARY); if (FC.CONFIG.boardType == 0 || FC.CONFIG.boardType == 2) { startLiveDataRefreshTimer(); } @@ -686,10 +685,10 @@ function have_sensor(sensors_detected, sensor_code) { function startLiveDataRefreshTimer() { // live data refresh - GUI.timeout_add('data_refresh', function () { update_live_status(); }, 100); + GUI.timeout_add('data_refresh', update_live_status, 100); } -function update_live_status() { +async function update_live_status() { const statuswrapper = $('#quad-status_wrapper'); @@ -698,75 +697,54 @@ function update_live_status() { }); if (GUI.active_tab !== 'cli' && GUI.active_tab !== 'presets') { - MSP.send_message(MSPCodes.MSP_BOXNAMES, false, false); - if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_32)) { - MSP.send_message(MSPCodes.MSP_STATUS_EX, false, false); - } else { - MSP.send_message(MSPCodes.MSP_STATUS, false, false); - } - MSP.send_message(MSPCodes.MSP_ANALOG, false, false); - } + await MSP.promise(MSPCodes.MSP_BOXNAMES); + await MSP.promise(semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_32) ? MSPCodes.MSP_STATUS_EX : MSPCodes.MSP_STATUS); + await MSP.promise(MSPCodes.MSP_ANALOG); - const active = ((Date.now() - FC.ANALOG.last_received_timestamp) < 300); + const active = ((Date.now() - FC.ANALOG.last_received_timestamp) < 300); - for (let i = 0; i < FC.AUX_CONFIG.length; i++) { - if (FC.AUX_CONFIG[i] === 'ARM') { - if (bit_check(FC.CONFIG.mode, i)) { - $(".armedicon").addClass('active'); - } else { - $(".armedicon").removeClass('active'); + for (let i = 0; i < FC.AUX_CONFIG.length; i++) { + if (FC.AUX_CONFIG[i] === 'ARM') { + $(".armedicon").toggleClass('active', bit_check(FC.CONFIG.mode, i)); + } + if (FC.AUX_CONFIG[i] === 'FAILSAFE') { + $(".failsafeicon").toggleClass('active', bit_check(FC.CONFIG.mode, i)); } } - if (FC.AUX_CONFIG[i] === 'FAILSAFE') { - if (bit_check(FC.CONFIG.mode, i)) { - $(".failsafeicon").addClass('active'); + + if (FC.ANALOG != undefined) { + let nbCells = Math.floor(FC.ANALOG.voltage / FC.BATTERY_CONFIG.vbatmaxcellvoltage) + 1; + + if (FC.ANALOG.voltage == 0) { + nbCells = 1; + } + + const min = FC.BATTERY_CONFIG.vbatmincellvoltage * nbCells; + const max = FC.BATTERY_CONFIG.vbatmaxcellvoltage * nbCells; + const warn = FC.BATTERY_CONFIG.vbatwarningcellvoltage * nbCells; + + const NO_BATTERY_VOLTAGE_MAXIMUM = 1.8; // Maybe is better to add a call to MSP_BATTERY_STATE but is not available for all versions + + if (FC.ANALOG.voltage < min && FC.ANALOG.voltage > NO_BATTERY_VOLTAGE_MAXIMUM) { + $(".battery-status").addClass('state-empty').removeClass('state-ok').removeClass('state-warning'); + $(".battery-status").css({ width: "100%" }); } else { - $(".failsafeicon").removeClass('active'); + $(".battery-status").css({ width: `${((FC.ANALOG.voltage - min) / (max - min) * 100)}%` }); + + if (FC.ANALOG.voltage < warn) { + $(".battery-status").addClass('state-warning').removeClass('state-empty').removeClass('state-ok'); + } else { + $(".battery-status").addClass('state-ok').removeClass('state-warning').removeClass('state-empty'); + } } } + + $(".linkicon").toggleClass('active', active); + + statuswrapper.show(); + GUI.timeout_remove('data_refresh'); + startLiveDataRefreshTimer(); } - - if (FC.ANALOG != undefined) { - let nbCells = Math.floor(FC.ANALOG.voltage / FC.BATTERY_CONFIG.vbatmaxcellvoltage) + 1; - - if (FC.ANALOG.voltage == 0) { - nbCells = 1; - } - - const min = FC.BATTERY_CONFIG.vbatmincellvoltage * nbCells; - const max = FC.BATTERY_CONFIG.vbatmaxcellvoltage * nbCells; - const warn = FC.BATTERY_CONFIG.vbatwarningcellvoltage * nbCells; - - const NO_BATTERY_VOLTAGE_MAXIMUM = 1.8; // Maybe is better to add a call to MSP_BATTERY_STATE but is not available for all versions - - if (FC.ANALOG.voltage < min && FC.ANALOG.voltage > NO_BATTERY_VOLTAGE_MAXIMUM) { - $(".battery-status").addClass('state-empty').removeClass('state-ok').removeClass('state-warning'); - $(".battery-status").css({ - width: "100%", - }); - } else { - $(".battery-status").css({ - width: `${((FC.ANALOG.voltage - min) / (max - min) * 100)}%`, - }); - - if (FC.ANALOG.voltage < warn) { - $(".battery-status").addClass('state-warning').removeClass('state-empty').removeClass('state-ok'); - } else { - $(".battery-status").addClass('state-ok').removeClass('state-warning').removeClass('state-empty'); - } - } - - } - - if (active) { - $(".linkicon").addClass('active'); - } else { - $(".linkicon").removeClass('active'); - } - - statuswrapper.show(); - GUI.timeout_remove('data_refresh'); - startLiveDataRefreshTimer(); } function specificByte(num, pos) { @@ -846,15 +824,14 @@ function reinitializeConnection(originatorTab, callback) { let attempts = 0; const reconnect = setInterval(waitforSerial, 100); - function waitforSerial() { + async function waitforSerial() { if (connectionTimestamp !== previousTimeStamp && CONFIGURATOR.connectionValid) { console.log(`Serial connection available after ${attempts / 10} seconds`); clearInterval(reconnect); - MSP.promise(MSPCodes.MSP_STATUS).then(() => { - GUI.log(i18n.getMessage('deviceReady')); - originatorTab.initialize(false, $('#content').scrollTop()); - callback?.(); - }); + await MSP.promise(MSPCodes.MSP_STATUS); + GUI.log(i18n.getMessage('deviceReady')); + originatorTab.initialize(false, $('#content').scrollTop()); + callback?.(); } else { attempts++; if (attempts > 100) { diff --git a/src/js/tabs/motors.js b/src/js/tabs/motors.js index ceab35a8..d21cbaca 100644 --- a/src/js/tabs/motors.js +++ b/src/js/tabs/motors.js @@ -585,9 +585,11 @@ TABS.motors.initialize = async function (callback) { // Amperage function power_data_pull() { - motorVoltage.text(i18n.getMessage('motorsVoltageValue', [FC.ANALOG.voltage])); - motorMahDrawingElement.text(i18n.getMessage('motorsADrawingValue', [FC.ANALOG.amperage.toFixed(2)])); - motorMahDrawnElement.text(i18n.getMessage('motorsmAhDrawnValue', [FC.ANALOG.mAhdrawn])); + if (FC.ANALOG.last_received_timestamp) { + motorVoltage.text(i18n.getMessage('motorsVoltageValue', [FC.ANALOG.voltage])); + motorMahDrawingElement.text(i18n.getMessage('motorsADrawingValue', [FC.ANALOG.amperage.toFixed(2)])); + motorMahDrawnElement.text(i18n.getMessage('motorsmAhDrawnValue', [FC.ANALOG.mAhdrawn])); + } } GUI.interval_add('motors_power_data_pull_slow', power_data_pull, 250, true); // 4 fps diff --git a/src/js/tabs/pid_tuning.js b/src/js/tabs/pid_tuning.js index db124771..0d72d225 100644 --- a/src/js/tabs/pid_tuning.js +++ b/src/js/tabs/pid_tuning.js @@ -1436,6 +1436,7 @@ TABS.pid_tuning.initialize = function (callback) { function process_html() { TABS.pid_tuning.isHtmlProcessing = true; FC.FEATURE_CONFIG.features.generateElements($('.tab-pid_tuning .features')); + self.checkUpdateProfile(false); if (semver.lt(FC.CONFIG.apiVersion, "1.16.0") || semver.gte(FC.CONFIG.apiVersion, "1.20.0")) { $('.tab-pid_tuning .pidTuningSuperexpoRates').hide();