# This file is part of the Metasploit Framework and may be subject to
|
|
# redistribution and commercial restrictions. Please see the Metasploit
|
|
# Framework web site for more information on licensing and terms of use.
|
|
# http://metasploit.com/framework/
|
|
##
|
|
|
|
require 'msf/core'
|
|
|
|
class Metasploit3 < Msf::Auxiliary
|
|
include Msf::Exploit::Remote::Tcp
|
|
include Msf::Auxiliary::Fuzzer
|
|
|
|
def initialize(info = {})
|
|
super(update_info(info,
|
|
'Name' => 'Modbus Unit ID and Station ID Enumerator',
|
|
'Description' => %q{
|
|
Modbus is a cleartext protocol used in common SCADA systems, developed
|
|
originally as a serial-line (RS232) async protocol, and later transformed
|
|
to IP, which is called ModbusTCP. default tcpport is 502.
|
|
|
|
This module sends a command (0x04, read input register) to the modbus endpoint.
|
|
If this command is sent to the correct unit-id, it returns with the same funcion-id.
|
|
if not, it should be added 0x80, so that it sys 0x84, and an exception-code follows
|
|
which do not interest us. This does not always happen, but at least the first 4
|
|
bytes in the return-packet should be exact the same as what was sent.
|
|
|
|
You can change port, ip and the scan-range for unit-id. There is also added a
|
|
value - BENICE - to make the scanner sleep a second or more between probes. We
|
|
have seen installations where scanning too many too fast works like a DoS.
|
|
},
|
|
'References' =>
|
|
[
|
|
[ 'URL', 'http://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx' ],
|
|
[ 'URL', 'http://en.wikipedia.org/wiki/Modbus:TCP' ]
|
|
],
|
|
'Author' => [ 'EsMnemon <esm[at]mnemonic.no>' ],
|
|
'License' => MSF_LICENSE,
|
|
'DisclosureDate' => 'Oct 28 2012'
|
|
))
|
|
|
|
register_options(
|
|
[
|
|
Opt::RPORT(502),
|
|
OptInt.new('UNIT_ID_FROM', [true, "ModBus Unit Identifier scan from value [1..254]", 1]),
|
|
OptInt.new('UNIT_ID_TO', [true, "ModBus Unit Identifier scan to value [UNIT_ID_FROM..254]", 254]),
|
|
OptInt.new('BENICE', [true, "Seconds to sleep between StationID-probes, just for beeing nice", 1]),
|
|
OptInt.new('TIMEOUT', [true, 'Timeout for the network probe, 0 means no timeout', 2])
|
|
], self.class)
|
|
end
|
|
|
|
def run
|
|
start="\x21\x00\x00\x00\x00\x06"
|
|
theend="\x04\x00\x01\x00\x00"
|
|
noll="\x00"
|
|
# between, \01..\0ff (1-255)
|
|
unless (1..255).include? datastore['UNIT_ID_FROM']
|
|
print_status("unit ID must be between 1 and 254 adjusting UNIT_ID_FROM to 1")
|
|
datastore['UNIT_ID_FROM']=1
|
|
end
|
|
|
|
unless (1..255).include? datastore['UNIT_ID_TO']
|
|
print_status("Unit ID must be between #{datastore['UNIT_ID_FROM']} and 255")
|
|
print_warning("Adjusting UNIT_ID_TO to #{datastore['UNIT_ID_FROM']} ")
|
|
datastore['UNIT_ID_TO'] = datastore['UNIT_ID_FROM']
|
|
end
|
|
|
|
if datastore['UNIT_ID_FROM'] > datastore['UNIT_ID_TO'] then
|
|
print_warning("UNIT_ID_TO is less than UNIT_ID_FROM, setting them equal")
|
|
datastore['UNIT_ID_TO'] = datastore['UNIT_ID_FROM']
|
|
end
|
|
|
|
datastore['UNIT_ID_FROM'].upto(datastore['UNIT_ID_TO']) do |counter|
|
|
sploit = start
|
|
sploit += [counter].pack("C")
|
|
sploit += theend
|
|
select(nil,nil,nil,datastore['BENICE'])
|
|
connect()
|
|
sock.put(sploit)
|
|
|
|
data = sock.get_once(12, datastore['TIMEOUT'])
|
|
if (data.nil?)
|
|
data=noll+noll+noll+noll
|
|
end
|
|
|
|
if data[0,4] == "\x21\x00\x00\x00" #return of the same trans-id+proto-id
|
|
print_good("Received: correct MODBUS/TCP from stationID #{counter}")
|
|
else
|
|
print_status("Received: incorrect/none data from stationID #{counter} (probably not in use)")
|
|
end
|
|
|
|
disconnect()
|
|
end
|
|
end
|
|
end
|
|
|
|
|
|
=begin
|
|
For testing purposes:
|
|
|
|
This client is developed and tested against a SAIA PCD1.M2 system
|
|
http://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx
|
|
and a modbus/tcp PLC simulator from plcsimulator.org
|
|
and the Modbus SLAVE from http://www.modbustools.com/
|
|
|
|
Mission is to find Unit-ID/stationID of the modbus-endpoint:
|
|
RHOST=IP of the modbus-service (PLC)
|
|
RPORT=Usually 502
|
|
=end
|