Change fail to fail_with, fix typo
parent
74f6ff7752
commit
e107ec2d17
|
@ -16,7 +16,7 @@ class Metasploit3 < Msf::Auxiliary
|
|||
'Name' => 'Veeder-Root Automatic Tank Gauge (ATG) Administrative Client',
|
||||
'Description' => %q{
|
||||
This module acts as a simplistic administrative client for interfacing
|
||||
with Veeder-Root Automatic Tang Gauges (ATGs) or other devices speaking
|
||||
with Veeder-Root Automatic Tank Gauges (ATGs) or other devices speaking
|
||||
the TLS-250 and TLS-350 protocols. This has been tested against
|
||||
GasPot, a honeypot meant to simulate ATGs; it has not been tested
|
||||
against anything else, so use at your own risk.
|
||||
|
@ -170,12 +170,18 @@ class Metasploit3 < Msf::Auxiliary
|
|||
|
||||
def setup
|
||||
# ensure that the specified command is implemented for the desired version of the TLS protocol
|
||||
fail "#{action.name} not defined for #{protocol}" unless action.opts.keys.include?(protocol_opt_name)
|
||||
unless action.opts.keys.include?(protocol_opt_name)
|
||||
fail_with(Failure::BadConfig, "#{action.name} not defined for #{protocol}")
|
||||
end
|
||||
|
||||
# ensure that the tank number is set for the commands that need it
|
||||
fail "TANK_NUMBER #{tank_number} is invalid" if action.name == 'SET_TANK_NAME' && (tank_number < 0 || tank_number > 99)
|
||||
if action.name == 'SET_TANK_NAME' && (tank_number < 0 || tank_number > 99)
|
||||
fail_with(Failure::BadConfig, "TANK_NUMBER #{tank_number} is invalid")
|
||||
end
|
||||
|
||||
fail "Invalid timeout #{timeout} -- must be > 0" unless timeout > 0
|
||||
unless timeout > 0
|
||||
fail_with(Failure::BadConfig, "Invalid timeout #{timeout} -- must be > 0")
|
||||
end
|
||||
end
|
||||
|
||||
def get_response(request)
|
||||
|
|
Loading…