@ -8,74 +8,200 @@ require 'msf/core'
class Metasploit3 < Msf::Auxiliary
include Msf::Exploit::Remote::Tcp
include Msf::Auxiliary::Fuzzer
def initialize(info = {})
super(update_info(info,
'Name' => 'Modbus Client Utility',
'Description' => %q{
This module sends a command (0x06, write to one register) to a Modbus endpoint.
You can change port, IP, register to write and data to write, as well as unit-id.
Modbus is a clear text protocol used in common SCADA systems, developed
originally as a serial-line (RS232) async protocol. It is later transformed
to IP, which is called ModbusTCP.
There are a handful of functions which are possible to do, but this
client has only implemented the function "write value to register" (\x48).
This module allows reading and writing data to a PLC using the Modbus protocol.
This module is based on the 'modiconstop.rb' Basecamp module from DigitalBond,
as well as the mbtget perl script.
},
'Author' => [ 'EsMnemon <esm[at]mnemonic.no>' ],
'References' =>
'Author' =>
[
['URL', 'http://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx']
'EsMnemon <esm[at]mnemonic.no>', # original write-only module
'Arnaud SOULLIE <arnaud.soullie[at]solucom.fr>' # new code that allows read/write
],
'License' => MSF_LICENSE,
'DisclosureDate' => 'Nov 1 2011'
'Actions' =>
[
['READ_COIL', { 'Description' => 'Read one bit from a coil' } ],
['WRITE_COIL', { 'Description' => 'Write one bit to a coil' } ],
['READ_REGISTER', { 'Description' => 'Read one word from a register' } ],
['WRITE_REGISTER', { 'Description' => 'Write one word to a register' } ]
],
'DefaultAction' => 'READ_REGISTER'
))
register_options([
register_options(
[
Opt::RPORT(502),
OptInt.new('UNIT_ID', [true, "ModBus Unit Identifier ", 1]),
OptInt.new('MODVALUE', [true, "ModBus value to write (data) ", 2]),
OptInt.new('REGIS', [true, "ModBus Register definition", 1002])
OptInt.new('DATA', [false, "Data to write (WRITE_COIL and WRITE_REGISTER modes only)"]),
OptInt.new('DATA_ADDRESS', [true, "Modbus data address"]),
OptInt.new('UNIT_NUMBER', [false, "Modbus unit number", 1]),
], self.class)
end
# a wrapper just to be sure we increment the counter
def send_frame(payload)
sock.put(payload)
@modbus_counter += 1
r = sock.get(sock.def_read_timeout)
return r
end
def make_payload(payload)
packet_data = [@modbus_counter].pack("n")
packet_data += "\x00\x00\x00" #dunno what these are
packet_data += [payload.size].pack("c") # size byte
packet_data += payload
packet_data
end
def make_read_payload
payload = [datastore['UNIT_NUMBER']].pack("c")
payload += [@function_code].pack("c")
payload += [datastore['DATA_ADDRESS']].pack("n")
payload += [1].pack("n")
packet_data = make_payload(payload)
packet_data
end
def make_write_coil_payload(data)
payload = [datastore['UNIT_NUMBER']].pack("c")
payload += [@function_code].pack("c")
payload += [datastore['DATA_ADDRESS']].pack("n")
payload += [data].pack("c")
payload += "\x00"
packet_data = make_payload(payload)
packet_data
end
def make_write_register_payload(data)
payload = [datastore['UNIT_NUMBER']].pack("c")
payload += [@function_code].pack("c")
payload += [datastore['DATA_ADDRESS']].pack("n")
payload += [data].pack("n")
packet_data = make_payload(payload)
packet_data
end
def handle_error(response)
case response.reverse.unpack("c")[0].to_i
when 1
print_error("Error : ILLEGAL FUNCTION")
when 2
print_error("Error : ILLEGAL DATA ADDRESS")
when 3
print_error("Error : ILLEGAL DATA VALUE")
when 4
print_error("Error : SLAVE DEVICE FAILURE")
when 6
print_error("Error : SLAVE DEVICE BUSY")
else
print_error("Unknown error")
end
return
end
def read_coil
@function_code = 0x1
print_status("Sending READ COIL...")
response = send_frame(make_read_payload)
if response.nil?
print_error("No answer for the READ COIL")
return
elsif response.unpack("C*")[7] == (0x80 | @function_code)
handle_error(response)
elsif response.unpack("C*")[7] == @function_code
value = response[9].unpack("c")[0]
print_good("Coil value at address #{datastore['DATA_ADDRESS']} : #{value}")
else
print_error("Unknown answer")
end
end
def read_register
@function_code = 3
print_status("Sending READ REGISTER...")
response = send_frame(make_read_payload)
if response.nil?
print_error("No answer for the READ REGISTER")
elsif response.unpack("C*")[7] == (0x80 | @function_code)
handle_error(response)
elsif response.unpack("C*")[7] == @function_code
value = response[9..10].unpack("n")[0]
print_good("Register value at address #{datastore['DATA_ADDRESS']} : #{value}")
else
print_error("Unknown answer")
end
end
def write_coil
@function_code = 5
if datastore['DATA'] == 0
data = 0
elsif datastore['DATA'] == 1
data = 255
else
print_error("Data value must be 0 or 1 in WRITE_COIL mode")
return
end
print_status("Sending WRITE COIL...")
response = send_frame(make_write_coil_payload(data))
if response.nil?
print_error("No answer for the WRITE COIL")
elsif response.unpack("C*")[7] == (0x80 | @function_code)
handle_error(response)
elsif response.unpack("C*")[7] == @function_code
print_good("Value #{datastore['DATA']} successfully written at coil address #{datastore['DATA_ADDRESS']}")
else
print_error("Unknown answer")
end
end
def write_register
@function_code = 6
if datastore['DATA'] < 0 || datastore['DATA'] > 65535
print_error("Data to write must be an integer between 0 and 65535 in WRITE_REGISTER mode")
return
end
print_status("Sending WRITE REGISTER...")
response = send_frame(make_write_register_payload(datastore['DATA']))
if response.nil?
print_error("No answer for the WRITE REGISTER")
elsif response.unpack("C*")[7] == (0x80 | @function_code)
handle_error(response)
elsif response.unpack("C*")[7] == @function_code
print_good("Value #{datastore['DATA']} successfully written at registry address #{datastore['DATA_ADDRESS']}")
else
print_error("Unknown answer")
end
end
def run
trans_id ="\x21\x00"
proto_id ="\x00\x00"
len ="\x00\x06"
func_id ="\x06"
#For debug: MODVALUE=19276 REGIS=18762, UNIT_ID=71
#trans_id="\x41\x42"
#proto_id="\x43\x44"
#len="\x45\x46"
#func_id="\x48"
sploit = trans_id
sploit += proto_id
sploit += len
sploit += [datastore['UNIT_ID']].pack("C")
sploit += func_id
sploit += [datastore['REGIS']].pack("S").reverse
sploit += [datastore['MODVALUE']].pack("S").reverse
connect()
sock.put(sploit)
sock.get_once
disconnect()
@modbus_counter = 0x0000 # used for modbus frames
connect
case action.name
when "READ_COIL"
read_coil
when "READ_REGISTER"
read_register
when "WRITE_COIL"
write_coil
when "WRITE_REGISTER"
write_register
else
print_error("Invalid ACTION")
end
disconnect
end
end
=begin
MODBUS: 10 00 00 00 00 06 01 06 03 ea 00 02
tested on a SAIA PCD1.M2
scapy - even with source-IP
sploit="\x21\x00\x00\x00\x00\x06\x01\x06\x03\xea\x00\x02"
ip=IP(dst="172.16.10.10",src="172.16.10.155",proto=6,flags=2)
tcp=TCP(dport=509)
send(ip/tcp/sploit)
=end