openwrt/target/linux/x86/generic
Baptiste Jonglez cd10577350 x86: Fix xen serial console by removing conflicting PATA driver
The Xen serial console has been broken since the xen_domu subtarget
was merged in the generic x86 subtarget (commits 1d6879ee and 371b382a).

The reason for the broken serial console seems to be an IRQ conflict
between the serial console driver and the PATA_LEGACY driver:

[    1.330125] genirq: Flags mismatch irq 8. 00000000 (hvc_console) vs. 00000000 (platform[pata_legacy.4])
[    1.330134] hvc_open: request_irq failed with rc -16.
[    1.330148] Warning: unable to open an initial console.

Just drop the PATA_LEGACY driver from the x86/generic and x86_64
subtargets, since this driver is marked experimental and only supports
very old ISA devices anyway.  It is still included in the x86/legacy
subtarget where it rightfully belongs.

Fixes: FS#787

Signed-off-by: Baptiste Jonglez <git@bitsofnetworks.org>
2017-07-16 11:31:52 +02:00
..
base-files/lib/preinit x86/generic: add xen DomU support 2017-01-16 20:40:13 +01:00
profiles x86: merge all geode based subtargets into one 2015-03-16 07:05:30 +00:00
config-default x86: Fix xen serial console by removing conflicting PATA driver 2017-07-16 11:31:52 +02:00
target.mk x86: enable fpu for all subtargets 2016-08-30 10:51:21 +02:00