ramips: fix ZyXEL Keenetic Viva switch config

The rtl8367b driver never supported a mdio property and it is quite
likely that the switch never worked for the board.

Use the mii-bus property instead to manage the switch via a mdio bus.

Signed-off-by: Franz Flasch <franz.flasch@gmx.at>
openwrt-19.07
Franz Flasch 2018-05-17 11:51:38 +02:00 committed by Mathias Kresin
parent d4ac26ec49
commit abb7524683
1 changed files with 1 additions and 1 deletions

View File

@ -78,7 +78,7 @@
compatible = "realtek,rtl8367b";
cpu_port = <7>;
realtek,extif2 = <1 0 1 1 1 1 1 1 2>;
mdio = <&mdio0>;
mii-bus = <&mdio0>;
};
};