openwrt-owl/target/linux/bcm53xx/patches-3.18/323-ARM-BCM5301X-Add-DT-for...

42 lines
1.4 KiB
Diff

From f3389cf7bc90d5702adcd4c100b49baf7a813bb9 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Rafa=C5=82=20Mi=C5=82ecki?= <zajec5@gmail.com>
Date: Wed, 28 Jan 2015 22:39:39 +0100
Subject: [PATCH] ARM: BCM5301X: Add DT for Netgear R8000
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
---
arch/arm/boot/dts/Makefile | 3 ++-
arch/arm/boot/dts/bcm4709-netgear-r8000.dts | 26 ++++++++++++++++++++++++++
2 files changed, 28 insertions(+), 1 deletion(-)
create mode 100644 arch/arm/boot/dts/bcm4709-netgear-r8000.dts
--- a/arch/arm/mach-bcm/bcm_5301x.c
+++ b/arch/arm/mach-bcm/bcm_5301x.c
@@ -18,15 +18,16 @@ static bool first_fault = true;
static int bcm5301x_abort_handler(unsigned long addr, unsigned int fsr,
struct pt_regs *regs)
{
- if (fsr == 0x1c06 && first_fault) {
+ if ((fsr == 0x1406 || fsr == 0x1c06) && first_fault) {
first_fault = false;
/*
- * These faults with code 0x1c06 happens for no good reason,
- * possibly left over from the CFE boot loader.
+ * These faults with codes 0x1406 (BCM4709) or 0x1c06 happens
+ * for no good reason, possibly left over from the CFE boot
+ * loader.
*/
pr_warn("External imprecise Data abort at addr=%#lx, fsr=%#x ignored.\n",
- addr, fsr);
+ addr, fsr);
/* Returning non-zero causes fault display and panic */
return 0;
--
1.8.4.5