kernel: rtl8306: fix vlan support on lantiq ar9 p2601hnfx

If the CPU port is not forced up, the link, at least on this board, is lost after
changes are applied. This makes sure that the link is restored. Regression tests
should confirm it doesn't break other boards.

Signed-off-by: Antonios Vamporakis <ant@area128.com>

SVN-Revision: 40305
owl
John Crispin 2014-03-30 09:15:16 +00:00
parent 72cdb34ae8
commit deba38f2a7
1 changed files with 4 additions and 0 deletions

View File

@ -126,6 +126,7 @@ enum rtl_regidx {
RTL_REG_EN_TAG_CLR,
RTL_REG_EN_TAG_IN,
RTL_REG_TRAP_CPU,
RTL_REG_CPU_LINKUP,
RTL_REG_TRUNK_PORTSEL,
RTL_REG_EN_TRUNK,
RTL_REG_RESET,
@ -194,6 +195,7 @@ static const struct rtl_reg rtl_regs[] = {
[RTL_REG_RESET] = { 0, 0, 16, 1, 12, 0 },
[RTL_REG_TRAP_CPU] = { 3, 2, 22, 1, 6, 0 },
[RTL_REG_CPU_LINKUP] = { 0, 6, 22, 1, 15, 0 },
[RTL_REG_VLAN_TAG_ONLY] = { 0, 0, 16, 1, 8, 1 },
[RTL_REG_VLAN_FILTER] = { 0, 0, 16, 1, 9, 1 },
@ -458,6 +460,8 @@ rtl_hw_apply(struct switch_dev *dev)
rtl_set(dev, RTL_REG_TRUNK_PORTSEL, trunk_psel);
rtl_phy_restore(dev, 5, &port5);
rtl_set(dev, RTL_REG_CPU_LINKUP, 1);